gemini-2.5-flash-lite-preview-09-2025| input-price: 0.1 output-price: 0.4 max-context-length: 128_000 (cost: $0.002) Β· Anfrage: 2025-12-13T18:29:02.827666

Generated by rs-summarizer Version unbekannt

Abstract:

The video demonstrates a procedure to measure the actual keying speed (dit/dah length) of a Kenwood TS-890 transceiver against its internal "words per minute" setting, leveraging the relationship $\text{Unit Length (s)} = 1.2 / \text{WPM}$. The author previously found discrepancies in other radios (KX2, TR45). The measurement is performed using a TinySA Ultra spectrum analyzer set to zero span mode, triggering on the transmitted pulses while the radio transmits into a dummy load. When set to 20 WPM, the measured unit interval is found to be $60.2 \text{ ms}$, confirming that the TS-890's setting is accurately implemented ($1.2 / 20 = 0.060 \text{ s}$). The procedure serves as a validation technique for Morse code timing accuracy in transceivers.

Validating Kenwood TS-890 Keying Speed Accuracy

Summary Rating: No ratings yet
Article Rating: No ratings yet

Source