Abstract:

This video provides an update on a previous review of the Leo Bodnar pulse generator, specifically addressing observed ringing artifacts. Initially, the generator was used with a 1 GHz Keysight oscilloscope, yielding a rise time of approximately 420 picoseconds but exhibiting noticeable ringing on the pulse edges. To clarify the source of this ringing, the pulse generator was subsequently tested on an ultra-high-bandwidth Keysight 62.3 GHz real-time oscilloscope. This high-fidelity measurement confirmed the pulse generator's impressive performance, measuring a rise time of roughly 20 picoseconds (well under its 30 ps specification), and crucially, showing no ringing. The findings conclusively demonstrate that the ringing observed on the lower-bandwidth oscilloscope was an artifact of its internal digital sinc/x filtering, validating the high quality of the Leo Bodnar pulse generator.

Exploring the Leo Bodnar Pulse Generator: Rise Time and Digital Filter Artifacts