gemini-2.5-pro| input-price: 1.25 output-price: 10 max-context-length: 200_000 (cost: $0.03) Β· Anfrage: 2025-10-18T08:00:11.236371

Generated by rs-summarizer Version unbekannt

Abstract:

This video documents the initial troubleshooting and repair of a vintage 1970s Cossor CRM.555, a precision signal generator for testing aircraft Instrument Landing Systems (ILS) and VOR navigation equipment. The unit was non-functional, immediately blowing its input fuse and drawing excessive current upon the first power-on attempt.

The initial diagnosis focuses on the power supply. Through reverse-engineering the schematic and using a thermal camera, the fault is traced to a misadjusted 20V power rail. The elevated voltage was triggering a Zener diode-based crowbar protection circuit, causing the short circuit condition. After correctly adjusting the power supply trimmer, the unit powers on with a normal current draw.

Subsequent functional tests reveal several remaining issues. While the carrier frequency generation for the Marker, Localizer, and Glide Path functions is largely operational, a faulty crystal prevents output at 109 MHz for both VOR and Localizer modes. Modulation testing confirms the Marker and Localizer functions are working correctly, but a critical fault is found in the VOR mode, which is missing its essential 30 Hz modulation. Additionally, the Glide Path modulation signal appears to be too high, causing saturation. The video concludes by summarizing these faults for a future repair session.

Troubleshooting a Vintage Cossor CRM.555 Aviation Test Set

Summary Rating: No ratings yet
Article Rating: No ratings yet

Source